Is your electric cooker oven tripping the electricity, MCB circuit breaker or RCD then it could be a break down of of the insulations resistance here i test the heating element to ensure its safe to use.
**Any insulation resistance testing is made on isolated dead equipment
If the insulation breaker down on your electric cooker oven wiring or the element itself internally it can cause your MCB to trip but more likely before that the RCD to trip. Its not only a good idea to test the electrical installations insulation resistance values but its the law on any new installation or even when replacing an existing shower for a new one. it makes sense to do similar on the cooker oven itself BUT only to the element as an insulation resistance use 250 or 500v to test, this can damage more sensitive electrical items and completely destroy electronics.
The test itself is very easy connect one end of leads to the electrical terminal of the element and the other to the body of the unit itself then press test , do this to both side if the element and to both elements of the shower heater. The result should be high Mohms if its lower 10 Mohms then you have an issue somewhere. The resistance of the insulation is breaking down and you need to rewire or buy new element.
Below is a video of testing the insulation resistance of element
Here i show insulation resistance testing of cooker oven heating element - using cheap test leads i electrocute myself at 3.45mins first time and it hurts and i also mess up Power calculation using 240v instead of 230v. 230v / 36.2 ohms = 6.35 amps , 230v x 6.35aps = 1460 watts or 1.46KW.
Buy cooker oven spares on Ebay UK here
Buy a good Multimeter on Ebay UK here
testing the installation video to follow ( TBC )